On 10/16/2013 06:25 PM, Graham Sortino wrote: > I’ve been testing out some thermocouples on my revised test stand and I > was wondering if there is a best practice for connecting the > thermocouple to the object** being measured? The best way is to spot weld each thermocouple wire to the metal object. > touched the tip of the thermocouple wire to my piece of metal. By doing this you have created an interesting thermodynamics problem. The wire is at a lower temperature and it begins to heat up when you touch it to the metal. The tip is pulling heat from the metal but the wire is cooling the tip. You are also cooling the metal but hopefully that is a small effect. It seems unlikely that this would ever give a good result. -- David W. Schultz http://home.earthlink.net/~david.schultz Returned for Regrooving