[AR] Re: Orions and PDEs (was Re: More MAX delays.)

  • From: "Troy Prideaux" <troy@xxxxxxxxxxxxxxxxxxxxx>
  • To: <arocket@xxxxxxxxxxxxx>
  • Date: Fri, 31 Jan 2020 13:28:20 +1100

Thanks Bob – also with some additional reading I now have a grasp. It’s the 
constant volume heating that allows large pressure ratios (Pc:Pe) without 
needing high pressure injection.

 

Funny that’s kinda my initial impression of how they worked, but this thread 
(particularly with the mention of rotary PDEs and some of the terminology) had 
me second guessing :)

 

Regards,

Troy

 

From: arocket-bounce@xxxxxxxxxxxxx [mailto:arocket-bounce@xxxxxxxxxxxxx] On ;
Behalf Of Robert Steinke
Sent: Friday, 31 January 2020 12:40 PM
To: arocket@xxxxxxxxxxxxx
Subject: [AR] Re: Orions and PDEs (was Re: More MAX delays.)

 

In a regular deflagration, the flame front is (relatively) slow so as the gas 
is heated it flows away from the flame and expands at constant pressure.

 

In a detonation, the flame front travels faster than the speed of sound. The 
gasses can’t flow away from the flame. They just can’t go that fast. The 
Reaction is all done before the gas can go anywhere so the effect is constant 
volume heat addition even if the gasses are not held in by any container. No 
work is done until after the heat addition is complete. 

 

On Thu, Jan 30, 2020 at 5:31 PM Anthony Cesaroni <anthony@xxxxxxxxxxx 
<mailto:anthony@xxxxxxxxxxx> > wrote:

Crickets huh? 😊

 

Anthony J. Cesaroni

President/CEO

Cesaroni Technology/Cesaroni Aerospace

 <http://www.cesaronitech.com/http://www.cesaronitech.com/

(941) 360-3100 x101 Sarasota

(905) 887-2370 x222 Toronto

 

-----Original Message-----
From:  <mailto:arocket-bounce@xxxxxxxxxxxxx> arocket-bounce@xxxxxxxxxxxxx < 
<mailto:arocket-bounce@xxxxxxxxxxxxx> arocket-bounce@xxxxxxxxxxxxx> On Behalf 
Of Troy Prideaux
Sent: Thursday, January 30, 2020 7:27 PM
To:  <mailto:arocket@xxxxxxxxxxxxx> arocket@xxxxxxxxxxxxx
Subject: [AR] Re: Orions and PDEs (was Re: More MAX delays.)

 

I'm totally lost with understanding this process. Can anyone describe the 
physical mechanism that enables PDEs to "theoretically" operate in a constant 
volume process?

 

Constant volume processes (to me) implies no work done by the working fluid. 
Yes there will be higher pressure and temperature outcomes because there's no 
work being done - but obviously I'm missing something. 

 

I'm guessing the detonation mechanism somehow uses more available energy for 
molecular translation and less going into molecular rotation? I'm curious to 
understand the mechanism.

 

Thanks,

 

Troy

Other related posts: